Solder Joint Reliability
AlphaSTAR Lead-free Reliability
BGA shear testing demonstrates that cohesive failures (i.e., fractures) take place within the solder, not at the solder/copper interface, thus demonstrating that the strongest possible solder joints are achieved by using the AlphaSTAR immersion silver process. The solder joint strength is independent of the silver thickness (0.05 - 0.5 µm) and reflow treatment (up to 3 times).
Schematic Diagram of Shear Test
Pad Diameter: 0.5 mm
Solder ball diameter: 0.76 mm